Steel
Building Dimensions
Whilst these specifications are given in good faith Conport Structures
reserves the right to change them without notice.
| |
|
| Building span |
9.0 m |
| Building length |
18.0 m |
| External ridge height |
4.8 m |
| Eaves height |
3.4 m |
| Standard door height |
2.0 m |
| Standard door width |
1.5 m |
| Effective floor area |
162 m² |
| Cladding module width |
1.0 m |
Design
Designed in accordance with "European recommendations for the
stressed skin design of steel buildings".
External Cladding
Colour coated buildings are coated with 200 Micron Plastisol finish
with a life to first maintenance of up to 25 years or with white lining
enamel for economy versions.
All cladding material is manufactured from "Galvatite", a
hot dipped zinc coated steel. The substrate is of grade Fe E280G commercial
quality mild steel with a minimum yield stress of 280 N/mm2 . Galvanised
coating is to a minimum thickness of 275 g/m2 with a conventional spangle
finish. The steel substrate fully complies with the provisions of British
Standard BSEN 10147: 1992.
All steel is profile rolled to comply with the provisions of BS 5427:
1976 in respect of materials, design, handling, working, performance
and storage.
Interior Cladding Sheet Materials
Similar to exterior cladding except that the coating is factory pre-painted
white lining enamel.
Sheetwork
Main Frame hot rolled steel sections Grade 43a.
Secondary steel framework cold rolled sections.
Steel work includes:
- Hot rolled Veerendahl trusses and supporting stanchions @ 3m c/c.
- Cold formed sheeting rails.
- Holding down bolts and erection bolts.
Protection
All hot rolled steel members shall be shot blasted to standard SA2.5
at works prior to fabrication. After fabrication one coat of good quality
zinc phosphate primer shall be applied by airless spray to 75 microns
nominal thickness.
All cold formed members shall be manufactured from pre galvanised strip.
Bolts
Anchor bolts shall be black and be complete with anchor plates nuts
and washers. Erection bolts shall be zinc plated.
Doors
Steel insulated double hinged doors with all furniture.
Insulation
Double steel skin with sound reducing insulating quilt to meet Building
regulations. Rubber strip to eliminate cold bridging.
Windows
Fixed light Double glazed widows with 4 top hung opening casements
in each bay.
All quotations are subject to our terms and conditions of sale,
a copy of which is available on request. Please do not hesitate to contact
us for further information.